Skip to main content

Table 5 Changes in displacement of the bladder base according to urinary incontinence

From: Vaginal palpation versus transabdominal ultrasound in the comprehension of pelvic floor muscle contraction after vaginal delivery: a randomised controlled trial

  Incontinent (n = 27) t value p value Continent (n = 38) t value p value
VP (n = 13) TAU (n = 14) VP (n = 19) TAU (n = 19)
Mean SD Mean SD Mean SD Mean SD
Displacement (mm)
 Pre 6.47 5.57 8.05 5.87    5.34 4.07 4.57 3.88   
 Post 7.22 4.07 7.10 3.82 6.69 2.78 5.53 4.19
Change 0.75 2.09  − 0.95 2.93 1.747 0.094 1.35 2.52 0.96 3.35 0.400 0.692
  1. VP vaginal palpation, TAU transabdominal ultrasound, SD standard deviation