Skip to main content

Table 2 Satisfaction survey results: percentage of women who positively endorsed* acceptability items by wearable sensor

From: Feasibility of three wearable sensors for 24 hour monitoring in middle-aged women

 

Actigraph GT3X+

GENEActiv

SenseWear Mini

N

(%)

N

(%)

N

(%)

N

21

19

20

Device acceptability

 Easy to wear

9

(42.90)

18

(94.70)

18

(90.00)

 Placement

10

(47.6)

13

(68.4)

16

(80.0)

 Comfortable during sleep

14

(66.7)

15

(78.9)

17

(85.0)

 7 Days too long

7

(35.0)

6

(31.6)

8

(45.0)

 24 h each day too long

8

(38.1)

7

(36.8)

8

(45.0)

 Log was inconvenient

4

(21.1)

5

(26.3)

6

(30.0)

Behavioral feedback content

 Moderate-vigorous physical activity feedback

21

(100.0)

15

(83.3)

20

(100.0)

 Light intensity activity feedback

18

(90.0)

15

(88.2)

17

(85.0)

 Sedentary activity feedback

17

(85.0)

15

(83.3)

18

(90.0)

 Sleep quantity/quality feedback

19

(100.0)

16

(100.0)

16

(84.2)

  1. *Positively endorsed = women agreed or strongly agreed