Skip to main content

Table 3 The diagnostic validity of the two scoring systems

From: Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study

Scoring system

AUC (95% CI)

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

Youden index

SRR

Ā Ā Ā Ā Ā Ā 

Overall patients

0.949 (0.899ā€“0.978)

97.5 (86.8ā€“99.9)

82.7 (74.0-89.4)

68.4 (58.7ā€“76.8)

98.9 (92.5ā€“99.8)

0.802

Premenopausal women

0.974 (0.912ā€“0.997)

100.0 (66.4ā€“100.0)

91.78 (83.0-96.9)

60.0 (41.1ā€“76.4)

100

0.918

Postmenopausal women

0.902 (0.800-0.963)

87.1 (70.2ā€“96.4)

80.7 (62.5ā€“92.5)

81.8 (68.4ā€“90.3)

86.2 (71.1ā€“94.1)

0.677

LR2

Ā Ā Ā Ā Ā Ā 

Overall patients

0.955 (0.907ā€“0.982)a

90.0 (76.5ā€“97.2)

89.4 (81.9ā€“94.6)

76.6 (65.0-85.2)

95.9 (90.2ā€“98.3)

0.794

Premenopausal women

0.939 (0.864ā€“0.980)b

100.0 (66.4ā€“100.0)

79.45 (68.4ā€“88.0)

37.5 (27.6ā€“48.5)

100

0.795

Postmenopausal women

0.935 (0.843ā€“0.982)c

96.77 (83.5ā€“99.9)

80.7 (62.5ā€“92.5)

83.3 (70.8ā€“91.1)

96.2 (78.3ā€“99.4)

0.774

  1. Note: AUC, area under the curve; PPV, positive predictive value; NPV, negative predictive value; CI, confidence interval; SRR, Simple Rules Risk; LR2, Logistic Regression Model 2;
  2. a: The Delong test P-value of AUC for SRR and LR2 in the overall patients is 0.766;
  3. b: The Delong test P-value of AUC for SRR and LR2 in premenopausal women is 0.371;
  4. c: The Delong test P-value of AUC for SRR and LR2 in postmenopausal women is 0.331